Flame atomic absorption spectrophotometry


(1) Direct method.

Method feed. After the metal ions in the water sample are atomized, they absorb the resonance lines from the hollow cathode lamp of the same metal elements (copper,324.7nm; Lead, 283.3 nm; Iron, 248.3 nm; Manganese, 279.5 nm; Zinc, 213, 9 nm; Cadmium,228.8nm, etc.), the amount of absorption resonance lines is proportional to the amount of this element in the sample. Under the condition of other conditions unchanged, according to the absorption of the measured spectral line intensity, compared with the standard series quantitative.


This method is suitable for the determination of scope: copper 0.2 ~ 5. Omg/L, iron 0.3 ~ 5. Omg/L, manganese 0.1 ~ 3. Omg/L, zinc 0.05 ~ 1.0 mg/L, copper 0.05 ~ 2. Omg/L, lead 1.0 ~ 20 mg/Lo2 reagent. The pure water used is deionized distilled water.


a. Various metal ion standards: ferrostatic standard reserve solution [p(Fe)=1mg/ml]. Weigh 1.000g pure iron powder [Fe content more than 99.9%] or 1.4300g iron oxide (Fe0, pure grade), add 100ml nitric acid solution (1+1), slowly heat and add hydrochloric acid (pa=1.19g/ml) to help dissolve, (reverse osmosis equipment) until completely dissolved, add pure water and volume to 1000ml.


b) Copper standard reserve solution [p(Cu)=lmg/mlJ. Weigh 1.000g pure copper powder [Cu content more than 99.9%], dissolve in 15ml nitric acid solution (1+1), and volume with pure water to 1000ml.


c) Manganese standard reserve solution [p(Mn)=1mg/ml]. Weigh 1.2912g manganese oxide (Mn0, superior pure) or 1.000g manganese metal [Mn content is more than 99.], add nitric acid solution (1+1) to dissolve, with pure water to 1,000ml.


d) Zinc standard reserve solution [p(Zn)=lmg/ml]. Weigh 1.0000g of pure zinc [the content of Zn is more than 99.9%] and dissolve in 20ml nitric acid solution (1+1), and volume with pure water to 1000ml. Zhongguanzhou I0 good sticky room when the In0E building


e) Cadmium standard reserve solution [p(Cd)=Img/ml]. Weigh 1.000g pure copper powder, dissolve in 5ml nitric acid solution (1+1), and use pure water to volume to 1000ml. Standard reserve solution of lead [p(Ph)=lmg/mlJ. Weigh 1.5985g dried lead nitrate [Ph(NO,)], dissolve in about 200ml-pure water, add 1.5ml nitric acid (poo=1.40g/ml), and volume with pure water to 1000ml. b. Nitric acid (p=1.42g/c. Hydrochloric acid (po=1.19g/ml), excellent pure.


温州九游会老哥环保设备科技有限公司

Official Service phones

0577-86864188

矿泉水设备 纯水机 去离子水设备

Manager:Mr. Sun
  • Tel:0086-577-86864188
  • Fax:0086-577-86864288
  • mobiles:0086-13819732151
  • Email:wzhdn3@haiyingbanjia.com
  • WebSite:Http://www.haiyingbanjia.com
  • Address:NO.568-A,3rd ROAD, BINHAI GARDEN, LONGWAN DISTRICT, WENZHOU CITY, CHINA
Copyright © @ Wenzhou Haineng environmental protection equipment Technology Co., Ltd.  技术支持:英捷互联 浙ICP备76583741号   
  • 主营:超纯水设备 纯化水设备 反渗透设备 水处理设备 去离子水设备 
  • Visit Count:
    九游会老哥